3-6 Fixture Operation DL.1 User Manual
Menu Option Descriptions
DMX Address Menu
DMX address is the top level menu selection used to set the fixture’s DMX start
channel. Use this menu option, set a start channel or to change the existing DMX
start channel to another DMX start channel.
Setting a DMX Start Channel
To set the DMX start channel:
1. Press the Menu button to unlock the menu system or to move back up the system
to the top level menus. DMX ADDRESS MENU is the first menu item at the top level.
2. Press the Enter button to select. The display will show SET DMX START
CHANNEL:###.The display shows the fixture’s currently assigned start channel.
3. Use the up and down arrows on the Navigation button to select the same DMX
start channel as the Media Server for the DL.1. The display will flash a new
option ready for selection.
Note: The last valid start channel for an DL.1 is based on the channel range
required by fixture’s protocol mode. The last valid start channel for the
DL.1 in standard mode (running without Digital Eye Technology) is 501
(512–12+1). The last valid start channel for the DL.1 in enhanced mode
(with Digital Eye Technology) is 493 (512–20+1).
4. Press the Enter button to accept the new DMX Start channel.
Note: If the Enter button is not pressed, the old value will remain selected after
exiting the menu.
Set Parameters Menu
The Set Parameters menu sets all factory options to their default settings or changes
the factory options individually.
Factory Default Settings
If any of the factory default settings are changed, this menu reverts to the OFF option.
The ON option restores all factory defaults.
To check and reset factory defaults:
1. Press the Menu button to unlock the menu system or to move back up the system
to the top level menus.
2. Using the left and right arrows on the Navigation button, scroll through the top
level to SET PARAMETERS MENU and press the Enter button to select.
3. Using the left and right arrows on the Navigation button, scroll to FACTORY
DEFAULT SETTINGS. The current state (ON or OFF) will be displayed.