2-14
Connecting Fixtures
Studio Color LCD Controller
4. Press the
<Enter>
button, then use the
<Up>
and
<Down>
arrow
buttons to select ADDR as shown below:
Figure 2-9. Configuring the fixture to be controlled by
fixture numbers rather than DMX 512 addresses.
5. Press the
<Enter>
button to save your selection, then keep
pressing the
<Menu>
button until ADDR is again displayed.
6. Repeat the procedure in the section titled “Setting A Fixture
Number” on page 2-11.
Cables and Terminators
There are two main types of cabling you can use: data-grade
cable and microphone cable. Although pin-compatible
microphone cable is suitable for small-scale designs, data
cable is recommended, especially for longer cable runs. Data
cable is designed to carry a higher-quality signal with less
susceptibility to electromagnetic interference.
The cable you use should have the characteristics listed
below:
2-conductor twisted pair plus a shield
maximum capacitance between conductors - 30 pF/ft.
maximum capacitance between conductor and shield - 55
pF/ft.
maximum resistance of 20 /1000 ft.
nominal impedance 100–140
22–24 AWG with insulation having a dielectric rating of
300 volts or higher
Belden 9841 data-grade cabling meets specifications for EIA
RS-485 applications and is highly recommended for use with
Studio Color.